Due to the high accuracy of the DataPhysics Instruments measuring devices measurements can be performed complying with various differnt international standards. In the following you can find an excerpt of the standards that can be complied:

ASTM C813

Standard Test Method for Hydrophobic Contamination on Glass by Contact Angle Measurement

The following measuring devices are suitable for measurements complying with the ASTM C813-90:

To the standardnavigate_next

ASTM D724

Standard Test Method for Surface Wettability of Paper (Angle-of-Contact Method)

Note: The ASTM D724 has been withdrawn by the standards organization ASTM International.

The following measuring devices are suitable for measurements complying with the ASTM D724:

To the standardnavigate_next

ASTM D971

Standard Test Method for Interfacial Tension of Oil Against Water by the Ring Method

The following measuring devices are suitable for measurements complying with the ASTM D971:

Application notenavigate_next To the standardnavigate_next

ASTM D1331

Standard Test Methods for Surface and Interfacial Tension of Solutions of Paints, Solvents, Solutions of Surface-Active Agents, and Related Materials

The following measuring devices are suitable for measurements complying with the ASTM D1331:

To the standardnavigate_next

ASTM D1417

Standard Test Methods for Rubber Latices—Synthetic

The following measuring devices are suitable for measurements complying with the ASTM D1417:

To the standardnavigate_next

ASTM D1590

Test Methods for Surface Tension of Water and Waste Water

Note: The ASTM D1590 has been withdrawn by the standards organization ASTM International.

The following measuring devices are suitable for measurements complying with the ASTM D1590:

To the standardnavigate_next

ASTM D2578

Standard Test Method for Wetting Tension of Polyethylene and Polypropylene Films

The following measuring devices are suitable for measurements complying with the ASTM D2578:

To the standardnavigate_next

ASTM D5725

Standard Test Method for Surface Wettability and Absorbency of Sheeted Materials Using an Automated Contact Angle Tester

Note: The ASTM D5725 has been withdrawn by the standards organization ASTM International.

The following measuring devices are suitable for measurements complying with the ASTM D5725:

To the standardnavigate_next

ASTM D5946

Standard Test Method for Corona-Treated Polymer Films Using Water Contact Angle Measurements

Note: The ASTM D5946 is identical to ISO 15989.

The following measuring devices are suitable for measurements complying with the ASTM D5946:

Application notenavigate_next To the standardnavigate_next

ASTM D7061

Standard Test Method for Measuring n-Heptane Induced Phase Separation of Asphaltene-Containing Heavy Fuel Oils as Separability Number by an Optical Scanning Device

The following measuring devices are suitable for measurements complying with the ASTM D7061:

To the standardnavigate_next

ASTM D7334

Standard Practice for Surface Wettability of Coatings, Substrates and Pigments by Advancing Contact Angle Measurement

The following measuring devices are suitable for measurements complying with the ASTM D7334:

To the standardnavigate_next

ASTM D7490

Standard Test Method for Measurement of the Surface Tension of Solid Coatings, Substrates and Pigments using Contact Angle Measurements

The following measuring devices are suitable for measurements complying with the ASTM D7490:

To the standardnavigate_next

ASTM D7541

Standard Practice for Estimating Critical Surface Tensions

The following measuring devices are suitable for measurements complying with the ASTM D7541:

To the standardnavigate_next

DIN 53593

Testing of latex; determination of surface tension

Note: The DIN 53593 has been withdrawn by the standards organization Deutsches Institut für Normung (DIN) and is being replaced by DIN ISO 1409 (ISO 1409).

The following measuring devices are suitable for measurements complying with the DIN 53593:

To the replacement standardnavigate_next

DIN 53914

Testing of surface active agents - Determination of surface tension

Note: The DIN 53914 has been withdrawn by the standards organization Deutsches Institut für Normung (DIN) and is being replaced by DIN EN 14370.

The following measuring devices are suitable for measurements complying with the DIN 53914:

To the replacement standardnavigate_next

DIN 55660

Paints and varnishes - Wettability

The following measuring devices are suitable for measurements complying with the DIN 55660:

To the standardnavigate_next

DIN EN 14210

Surface active agents - Determination of interfacial tension of solutions of surface active agents by the stirrup or ring method

The following measuring devices are suitable for measurements complying with the DIN EN 14210:

To the standardnavigate_next

DIN EN 14370

Surface active agents - Determination of surface tension

The following measuring devices are suitable for measurements complying with the DIN EN 14210:

To the standardnavigate_next

DIN EN 15802

Conservation of cultural property - Test methods - Determination of static contact angle

The following measuring devices are suitable for measurements complying with the DIN 55660:

To the standardnavigate_next

ISO 304

Surface active agents — Determination of surface tension by drawing up liquid films

The following measuring devices are suitable for measurements complying with the ISO 304:

To the standardnavigate_next

ISO 1409

Plastics/rubber — Polymer dispersions and rubber latices (natural and synthetic) — Determination of surface tension by the ring method

The following measuring devices are suitable for measurements complying with the ISO 1409:

To the standardnavigate_next

ISO 4311

Anionic and non-ionic surface active agents — Determination of the critical micellization concentration — Method by measuring surface tension with a plate, stirrup or ring

The following measuring devices are suitable for measurements complying with the ISO 4311:

To the standardnavigate_next

ISO 6295

Petroleum products — Mineral oils — Determination of interfacial tension of oil against water — Ring method

Note: The ISO 6295 has been withdrawn by the standards organization International Organization for Standardization (ISO).

The following measuring devices are suitable for measurements complying with the ISO 6295:

To the standardnavigate_next

ISO 6889

Surface active agents — Determination of interfacial tension by drawing up liquid films

The following measuring devices are suitable for measurements complying with the ISO 6889:

To the standardnavigate_next

ISO 8296

Plastics — Film and sheeting — Determination of wetting tension

The following measuring devices are suitable for measurements complying with the ISO 8296:

To the standardnavigate_next

ISO 15989

Plastics — Film and sheeting — Measurement of water-contact angle of corona-treated films

Note: The ASTM D5946 is identical to ISO 15989.

The following measuring devices are suitable for measurements complying with the ISO 15989:

Application notenavigate_next To the standardnavigate_next

ISO 19403

Paints and varnishes — Wettability — [Part 1 to 7]

The following measuring devices are suitable for measurements complying with the ISO 19403:

To the standardnavigate_next

ISO 27448

Fine ceramics (advanced ceramics, advanced technical ceramics) — Test method for self-cleaning performance of semiconducting photocatalytic materials — Measurement of water contact angle

The following measuring devices are suitable for measurements complying with the ISO 27448:

To the standardnavigate_next

OECD 115

Surface Tension of Aqueous Solutions

The following measuring devices are suitable for measurements complying with the OECD 115:

To the standardnavigate_next

IEC 62961

Insulating liquids - Test methods for the determination of interfacial tension of insulating liquids - Determination with the ring method

The following measuring devices are suitable for measurements complying with the IEC 62961:

To the standardnavigate_next

IEC TS 62073

Guidance on the measurement of hydrophobicity of insulator surfaces

The following measuring devices are suitable for measurements complying with the IEC TS 62073:

To the standardnavigate_next

Official Journal of the EC L251/37 A.5. (Volume 27)

Surface Tension

Note: The Commission Directive is no longer in force.

The following measuring devices are suitable for measurements complying with the Official Journal of the EC L251/37 A.5.:

To the standardnavigate_next